mirror of
https://git.gnunet.org/libmicrohttpd.git
synced 2026-10-03 04:03:18 +03:00
MHD_get_timeout*(): improved doxy
This commit is contained in:
2 files changed
+34
-24
No files matched your search
+13
-10
@@ -2902,10 +2902,11 @@ MHD_get_fdset2 (struct MHD_Daemon *daemon,
|
||||
* return #MHD_YES will break MHD processing logic and result in "hung"
|
||||
* connections with data pending in network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns #MHD_YES then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD fds.
|
||||
* It is important to always use this function (or #MHD_get_timeout64(),
|
||||
* #MHD_get_timeout64s() functions) when "external" polling is used.
|
||||
* If this function returns #MHD_YES then #MHD_run() (or #MHD_run_from_select())
|
||||
* must be called right after return from polling function, regardless of
|
||||
* the states of MHD FDs.
|
||||
*
|
||||
* In practice, if #MHD_YES is returned then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called not later than @a timeout
|
||||
@@ -2937,10 +2938,11 @@ MHD_get_timeout (struct MHD_Daemon *daemon,
|
||||
* return #MHD_YES will break MHD processing logic and result in "hung"
|
||||
* connections with data pending in network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns #MHD_YES then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD fds.
|
||||
* It is important to always use this function (or #MHD_get_timeout(),
|
||||
* #MHD_get_timeout64s() functions) when "external" polling is used.
|
||||
* If this function returns #MHD_YES then #MHD_run() (or #MHD_run_from_select())
|
||||
* must be called right after return from polling function, regardless of
|
||||
* the states of MHD FDs.
|
||||
*
|
||||
* In practice, if #MHD_YES is returned then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called not later than @a timeout
|
||||
@@ -2975,8 +2977,9 @@ MHD_get_timeout64 (struct MHD_Daemon *daemon,
|
||||
* processing logic and result in "hung" connections with data pending in
|
||||
* network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns non-negative value then #MHD_run() (or
|
||||
* It is important to always use this function (or #MHD_get_timeout(),
|
||||
* #MHD_get_timeout64() functions) when "external" polling is used.
|
||||
* If this function returns non-negative value then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD FDs.
|
||||
*
|
||||
|
||||
+21
-14
@@ -3895,15 +3895,16 @@ MHD_cleanup_connections (struct MHD_Daemon *daemon)
|
||||
* return #MHD_YES will break MHD processing logic and result in "hung"
|
||||
* connections with data pending in network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns #MHD_YES then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD fds.
|
||||
* It is important to always use this function (or #MHD_get_timeout64(),
|
||||
* #MHD_get_timeout64s() functions) when "external" polling is used.
|
||||
* If this function returns #MHD_YES then #MHD_run() (or #MHD_run_from_select())
|
||||
* must be called right after return from polling function, regardless of
|
||||
* the states of MHD FDs.
|
||||
*
|
||||
* In practice, if #MHD_YES is returned then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called not later than @a timeout
|
||||
* millisecond even if not activity is detected on sockets by
|
||||
* sockets polling function.
|
||||
* millisecond even if no activity is detected on sockets by sockets
|
||||
* polling function.
|
||||
* @remark To be called only from thread that process
|
||||
* daemon's select()/poll()/etc.
|
||||
*
|
||||
@@ -3945,15 +3946,18 @@ MHD_get_timeout (struct MHD_Daemon *daemon,
|
||||
* return #MHD_YES will break MHD processing logic and result in "hung"
|
||||
* connections with data pending in network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns #MHD_YES then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD fds.
|
||||
* It is important to always use this function (or #MHD_get_timeout(),
|
||||
* #MHD_get_timeout64s() functions) when "external" polling is used.
|
||||
* If this function returns #MHD_YES then #MHD_run() (or #MHD_run_from_select())
|
||||
* must be called right after return from polling function, regardless of
|
||||
* the states of MHD FDs.
|
||||
*
|
||||
* In practice, if #MHD_YES is returned then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called not later than @a timeout
|
||||
* millisecond even if not activity is detected on sockets by
|
||||
* sockets polling function.
|
||||
* millisecond even if no activity is detected on sockets by sockets
|
||||
* polling function.
|
||||
* @remark To be called only from thread that process
|
||||
* daemon's select()/poll()/etc.
|
||||
*
|
||||
* @param daemon daemon to query for timeout
|
||||
* @param timeout64 the pointer to the variable to be set to the
|
||||
@@ -4053,8 +4057,9 @@ MHD_get_timeout64 (struct MHD_Daemon *daemon,
|
||||
* processing logic and result in "hung" connections with data pending in
|
||||
* network buffers and other problems.
|
||||
*
|
||||
* It is important to always use this function when "external" polling is
|
||||
* used. If this function returns non-negative value then #MHD_run() (or
|
||||
* It is important to always use this function (or #MHD_get_timeout(),
|
||||
* #MHD_get_timeout64() functions) when "external" polling is used.
|
||||
* If this function returns non-negative value then #MHD_run() (or
|
||||
* #MHD_run_from_select()) must be called right after return from polling
|
||||
* function, regardless of the states of MHD FDs.
|
||||
*
|
||||
@@ -4062,6 +4067,8 @@ MHD_get_timeout64 (struct MHD_Daemon *daemon,
|
||||
* #MHD_run_from_select()) must be called not later than returned amount of
|
||||
* millisecond even if no activity is detected on sockets by sockets
|
||||
* polling function.
|
||||
* @remark To be called only from thread that process
|
||||
* daemon's select()/poll()/etc.
|
||||
*
|
||||
* @param daemon the daemon to query for timeout
|
||||
* @return -1 if connections' timeouts are not set and no data processing
|
||||
|
||||
Reference in new issue
Block a user